Skip to main content

Fluorescent Dyes for Peptides

Fluorescent Dyes for Peptide Labeling

Choosing a dye is usually a choice between dyes in the same channel rather than between colours. The colour is set by the instrument you have; what is left to decide is whether the label will survive the acquisition, whether its signal depends on pH, how it is attached, and what it costs. Each page below answers those questions for one dye.

Four questions decide most dye choices. Which laser and filters does the instrument have? Will the peptide meet a pH below about 7, as it will inside an endosome? Will the same field be imaged repeatedly, or read once? And does the label have to survive months of storage? A fluorescein answers the first well and the others poorly; that is the trade most of these pages are about.

Green — 488 nm excitation

DyeExcitationEmissionLaser lineWhy it is chosen
FITC495 nm519 nm488 nmThe economical green label. Requires an Ahx or β-Ala spacer at the N-terminus.
FAM494 nm519 nm488 nmFluorescein through an amide bond; the usual green choice for a peptide you will store.
Alexa Fluor 488495 nm519 nm488 nmFluorescein's channel without its pH dependence or its photobleaching.
HiLyte Fluor 488501 nm527 nm488 nmGreen channel alternative with less pH dependence than fluorescein.
ATTO 488501 nm523 nm488 nmGreen dye built for demanding microscopy.

Orange and red — 532 to 561 nm

DyeExcitationEmissionLaser lineWhy it is chosen
TAMRA556 nm580 nm543 nm, 561 nmThe standard orange acceptor opposite a fluorescein donor; pH-independent.
Rhodamine (TRITC)547 nm572 nm543 nm, 561 nmTRITC and the rhodamine class; see TAMRA for the amide-linked form.
Cy3550 nm570 nm532 nm, 561 nmBright orange cyanine; donor half of the Cy3–Cy5 FRET pair.
ATTO 550554 nm576 nm543 nm, 561 nmOrange channel where photobleaching limits the experiment.

Far red — 633 to 640 nm

DyeExcitationEmissionLaser lineWhy it is chosen
Cy5646 nm662 nm633 nm, 640 nmFar red, below most autofluorescence; acceptor for Cy3.
Alexa Fluor 647650 nm668 nm633 nm, 640 nmCy5's channel, more photostable.
ATTO 647N644 nm669 nm633 nm, 640 nmAmong the most photostable far-red dyes; the most hydrophobic here.

Near infrared — for imaging through tissue

DyeExcitationEmissionLaser lineWhy it is chosen
Cy5.5675 nm694 nm673 nm, 685 nmFirst of the series useful for imaging through tissue.
Cy7750 nm773 nm750 nmNear infrared for whole-animal imaging and biodistribution.
Cy7.5788 nm808 nm785 nmLongest wavelength offered; greatest tissue penetration.

Quencher

DyeExcitationEmissionLaser lineWhy it is chosen
QSY 9560 nm——Dark quencher for fluorogenic substrates; absorbs, does not emit.

Three cautions that apply to all of them

  • Published maxima vary. These dyes are environmentally sensitive, different solvents and applications give different results, and the literature frequently quotes different values for the same dye. There are also several sub-varieties of most of them. Confirm filters against the conjugate you have rather than against a generic table.
  • Isothiocyanates need a spacer on a peptide N-terminus. FITC and TRITC both form a thiourea, and on an α-amino group that is the arrangement acid uses to cleave off the first residue. An Ahx or β-alanine spacer prevents it.
  • Position can matter more than the dye. A label placed in or next to a binding motif can remove the activity being measured. Tell us what the peptide has to do, not only its sequence.

Further reading