Fluorescent Dyes for Peptide Labeling
Choosing a dye is usually a choice between dyes in the same channel rather than between colours. The colour
is set by the instrument you have; what is left to decide is whether the label will survive the acquisition,
whether its signal depends on pH, how it is attached, and what it costs. Each page below answers those
questions for one dye.
Four questions decide most dye choices. Which laser and filters does the instrument have?
Will the peptide meet a pH below about 7, as it will inside an endosome? Will the same field be imaged
repeatedly, or read once? And does the label have to survive months of storage? A fluorescein answers the
first well and the others poorly; that is the trade most of these pages are about.
Green — 488 nm excitation
| Dye | Excitation | Emission | Laser line | Why it is chosen |
| FITC | 495 nm | 519 nm | 488 nm | The economical green label. Requires an Ahx or β-Ala spacer at the N-terminus. |
| FAM | 494 nm | 519 nm | 488 nm | Fluorescein through an amide bond; the usual green choice for a peptide you will store. |
| Alexa Fluor 488 | 495 nm | 519 nm | 488 nm | Fluorescein's channel without its pH dependence or its photobleaching. |
| HiLyte Fluor 488 | 501 nm | 527 nm | 488 nm | Green channel alternative with less pH dependence than fluorescein. |
| ATTO 488 | 501 nm | 523 nm | 488 nm | Green dye built for demanding microscopy. |
Orange and red — 532 to 561 nm
| Dye | Excitation | Emission | Laser line | Why it is chosen |
| TAMRA | 556 nm | 580 nm | 543 nm, 561 nm | The standard orange acceptor opposite a fluorescein donor; pH-independent. |
| Rhodamine (TRITC) | 547 nm | 572 nm | 543 nm, 561 nm | TRITC and the rhodamine class; see TAMRA for the amide-linked form. |
| Cy3 | 550 nm | 570 nm | 532 nm, 561 nm | Bright orange cyanine; donor half of the Cy3–Cy5 FRET pair. |
| ATTO 550 | 554 nm | 576 nm | 543 nm, 561 nm | Orange channel where photobleaching limits the experiment. |
Far red — 633 to 640 nm
| Dye | Excitation | Emission | Laser line | Why it is chosen |
| Cy5 | 646 nm | 662 nm | 633 nm, 640 nm | Far red, below most autofluorescence; acceptor for Cy3. |
| Alexa Fluor 647 | 650 nm | 668 nm | 633 nm, 640 nm | Cy5's channel, more photostable. |
| ATTO 647N | 644 nm | 669 nm | 633 nm, 640 nm | Among the most photostable far-red dyes; the most hydrophobic here. |
Near infrared — for imaging through tissue
| Dye | Excitation | Emission | Laser line | Why it is chosen |
| Cy5.5 | 675 nm | 694 nm | 673 nm, 685 nm | First of the series useful for imaging through tissue. |
| Cy7 | 750 nm | 773 nm | 750 nm | Near infrared for whole-animal imaging and biodistribution. |
| Cy7.5 | 788 nm | 808 nm | 785 nm | Longest wavelength offered; greatest tissue penetration. |
Quencher
| Dye | Excitation | Emission | Laser line | Why it is chosen |
| QSY 9 | 560 nm | — | — | Dark quencher for fluorogenic substrates; absorbs, does not emit. |
Three cautions that apply to all of them
- Published maxima vary. These dyes are environmentally sensitive, different solvents and
applications give different results, and the literature frequently quotes different values for the same dye.
There are also several sub-varieties of most of them. Confirm filters against the conjugate you have rather
than against a generic table.
- Isothiocyanates need a spacer on a peptide N-terminus. FITC and TRITC both form a
thiourea, and on an α-amino group that is the arrangement acid uses to cleave off the first residue.
An Ahx or β-alanine spacer prevents it.
- Position can matter more than the dye. A label placed in or next to a binding motif can
remove the activity being measured. Tell us what the peptide has to do, not only its sequence.
Further reading