LifeTein synthesizes fluorescently labeled peptides for microscopy, flow cytometry, cellular uptake and localization studies, binding assays, FRET protease substrates and in vivo imaging. The labels most often used in published peptide work are available as standard: FITC and FAM, rhodamine B and TAMRA, Alexa Fluor 488 and 647, the cyanine dyes Cy3, Cy5, Cy5.5 and Cy7, and donor–quencher pairs such as EDANS/Dabcyl and MCA/DNP. Other dyes can be quoted on request.
| Common dyes | FITC, 5(6)-FAM, rhodamine B, TAMRA, Alexa Fluor 488, Alexa Fluor 647, Cy3, Cy5, Cy5.5, Cy7, BODIPY FL, MCA, Abz and EDANS/Dabcyl; other dyes on request |
| Attachment chemistry | On-resin coupling during synthesis; maleimide labeling of a cysteine thiol, our preferred route for attaching a dye to a finished peptide; NHS ester labeling of amines |
| Applications | FRET assays, fluorescence microscopy, flow cytometry, intracellular delivery studies, localization studies, enzyme substrate design, and peptide-protein interaction studies |
| Labeling positions | N-terminus, C-terminus, Lys side chain, Cys side chain, and other sequence-dependent positions |
| Spacer options | Ahx, β-Ala, PEG spacers, and other linkers to improve dye accessibility and reduce steric interference |
| Peptide formats | Fluorescent peptides, quenched substrates, donor-acceptor FRET peptides, near-infrared labeled peptides, cyclic fluorescent peptides, and dye-labeled cell-penetrating peptides |
| Technical support | Dye selection, spacer recommendation, labeling-position review, and sequence-specific feasibility evaluation |
Select a dye to view excitation/emission spectra and recommended laser compatibility.
Dashed line = excitation, solid line = emission. Vertical markers indicate common laser lines for the selected dye. Curves are representative; published maxima shift with the derivative, the solvent and the attachment.
Ex/Em: 495/519 nm
Molecular Weight: 389
Laser: 488 nm
Filters: 530/30
Description:
Classic green fluorophore widely used for peptide labeling, microscopy, flow cytometry, and intracellular tracking.
Typical Applications:
Use the sections below to compare dye options, review FRET peptide designs, understand labeling chemistry, and view representative LifeTein case studies.
Dye selection depends on the assay format, excitation source, emission channel, desired brightness, photostability, peptide solubility, and whether the peptide will be used in live cells, fixed cells, purified biochemical assays, or in vivo imaging models.
The dyes below are the ones that appear most often in published peptide work, and between them they cover the laser lines found on most microscopes and flow cytometers. Wavelengths are approximate: published maxima differ between derivatives, solvents and suppliers.
| Dye | Approx. Ex/Em | Typical use | How it is attached, and what to watch |
|---|---|---|---|
| FITC | 495/519 nm | Microscopy, flow cytometry, uptake studies | Isothiocyanate coupled on resin, giving a thiourea. Economical. Fluorescence falls in acidic environments such as endosomes. |
| 5(6)-FAM | 492/517 nm | Green label, FRET donor, fluorescence polarization | Carboxylic acid coupled on resin, giving an amide. The same fluorescein chromophore as FITC, but a different reagent and a different linkage. |
| Alexa Fluor 488 | ~495/519 nm | Demanding imaging in the 488 nm channel | Maleimide to a cysteine, or NHS ester. Reported to be brighter and more photostable than fluorescein, and insensitive to pH between 4 and 10.3 |
| BODIPY FL | ~503/512 nm | Green label, fluorescence polarization | Maleimide or NHS ester. Uncharged and relatively hydrophobic, which can affect peptide solubility. |
| Rhodamine B | ~555/580 nm | Red-orange label for imaging and uptake studies | Our usual rhodamine label, coupled on resin as the carboxylic acid. See the note on spirolactam formation under Labeling Chemistry. TRITC and TAMRA are available on request. |
| TAMRA | ~555/580 nm | Red-orange label, FRET acceptor for fluorescein donors | Carboxylic acid coupled on resin, or maleimide or NHS ester after synthesis. |
| Cy3 | ~550/570 nm | Orange channel, FRET donor for Cy5 | Maleimide or NHS ester. Sulfonated forms carry charge and are more water-soluble. |
| Cy5, Alexa Fluor 647 | ~650/665 nm | Far-red imaging, where cellular autofluorescence is lower | Maleimide or NHS ester. |
| Cy5.5, Cy7 | ~675/694 and ~750/775 nm | Near-infrared imaging, including in small animals | Maleimide or NHS ester. Near-infrared light penetrates tissue further and meets less autofluorescence.4 |
| MCA, Abz, EDANS | UV excitation, blue emission | Donors in internally quenched protease substrates | Coupled during synthesis and paired with a quencher such as DNP, Tyr(NO2) or Dabcyl. See the FRET Peptides tab. |
Other labels, including ATTO, DyLight, Texas Red, ROX and near-infrared dyes, can be quoted on request. Tell us the dye and the reactive form you need.
Fluorescence resonance energy transfer, or FRET, is a distance-dependent fluorescence method used to study molecular proximity, peptide cleavage, enzyme activity, conformational change, and protein-protein association. In a typical FRET peptide substrate, a donor fluorophore and acceptor dye or quencher are placed on the same peptide. When the peptide is intact, fluorescence is quenched or transferred. After enzymatic cleavage or conformational change, the fluorescence signal changes.
Energy transfer depends on spectral overlap between donor emission and acceptor absorption, on the relative orientation of the two, and on the distance between them. It is most sensitive over distances on the nanometer scale, around the Förster radius of the particular pair; the table below gives Förster radii for several pairs used in peptide work. The acceptor may be a second fluorophore or a nonfluorescent dark quencher.
The design introduced by Matayoshi and colleagues for retroviral proteases: the donor EDANS and the quencher Dabcyl sit on either side of the cleavage site. In the intact peptide Dabcyl quenches EDANS; cleavage separates them and EDANS fluorescence is detected at about 490 nm.9
The spectral overlap behind the pair: EDANS absorption and emission with Dabcyl absorption. Dabcyl absorbs across the EDANS emission band, which is what makes it an efficient quencher for this donor.
Useful FRET calculator: FPbase FRET Calculator
| Quencher | Fluorophore | Excitation | Emission |
|---|---|---|---|
| Dabcyl | EDANS | 336 nm | 490 nm |
| Dansyl | Trp | 336 nm | 350 nm |
| DNP | MCA | 328 nm | 393 nm |
| Tyr(NO2) | Abz | 320 nm | 420 nm |
| Donor | Acceptor | Förster Distance |
|---|---|---|
| Trp | Dansyl | 2.1 nm |
| Dansyl | FITC | 3.3–4.1 nm |
| Dansyl | Rhodamine | 4.3 nm |
| FITC | Tetramethylrhodamine | 4.9–5.5 nm |
| Cy3 | Cy5 | >5.0 nm |
Fluorescent peptide Angiotensin 1-7 with the FRET pair Abz/[Tyr7(NO2)] was synthesized by LifeTein. This peptide was used to study Ang-(1-7) endopeptidase activity in the renal renin angiotensin system.
“100 µM Abz-Ang-(1-7)-[Tyr7(NO2)], an internally quenched fluorescent peptide (synthesized by LifeTein, South Plainfield, NJ, USA)…”
Fluorescent dyes can be introduced at the N-terminus, C-terminus, Lys side chain, Cys side chain, or other engineered positions depending on the peptide sequence and application. The best labeling strategy depends on whether the dye must avoid the active binding motif, whether the peptide requires a free terminus, and whether a spacer is needed.
Most dyes are available in both reactive forms. For a peptide that contains a cysteine, or that can take one at a position you do not need for activity, maleimide labeling gives the cleanest single product.
FITC is the most widely used green label for peptides. It is an isothiocyanate, so it reacts with primary amines, at the N-terminus or at a selectively deprotected lysine, and forms a thiourea rather than an amide. FAM is the same fluorescein chromophore supplied as a carboxylic acid, which couples as an amide; the two are different reagents and should be specified separately on an order.
A spacer such as aminohexanoic acid (Ahx) is usually placed between an N-terminal fluorescein label and the sequence. It separates a bulky dye from the peptide's active region, and it also addresses a known side reaction: under the acidic conditions used to cleave the peptide from the resin, an N-terminal FITC label can cyclize and take the first residue with it, forming a thiohydantoin and leaving a shortened, fluorescein-labeled peptide.5 An Ahx or β-Ala spacer, which is what we add by default, removes that risk, and we review the sequence before synthesis either way.
Rhodamine B is our usual rhodamine label and is coupled on resin as the carboxylic acid. It is red-orange, and more photostable and far less pH-sensitive than fluorescein. One point is worth knowing at the design stage: when rhodamine B is joined to a primary amine, the resulting amide can close onto the xanthene ring to form a colorless, nonfluorescent spirolactam, and that equilibrium depends on pH and environment.6 Published work avoids this by coupling rhodamine B through a secondary amine or a sarcosine-type linker,7 and TAMRA, where the carboxyl sits at the 5- or 6-position, does not close in the same way. If your assay runs across a range of pH values, tell us and we will recommend the linker or the dye accordingly.
TRITC, the isothiocyanate form of tetramethylrhodamine, and TAMRA, the carboxylic acid form of the same chromophore, are both available. They are different reagents and give different linkages.
Fluorescent dyes are bulky aromatic molecules, so a spacer is often placed between the dye and the peptide's active region. A spacer can help preserve binding or uptake, but it changes the molecule too and the result should be checked experimentally rather than assumed.
LifeTein synthesized a peptide encompassing the ZnF region (a.a. 1–75) of human IRF2BPL with an N-terminal FITC tag linked through a 6-aminohexanoic acid (Ahx) spacer, C-terminal amidation, and >90% purity. This is a representative example of a long, fluorescently labeled peptide prepared for advanced cell and protein studies.
“FITC-Tet1, Alexa 594-N1, and Atto 643-N1 (95% purity) were acquired from LifeTein (NJ)...”
Fluorescence seen inside cells does not by itself establish that intact peptide reached the cytosol: surface binding, endosomal trapping and dye-containing fragments can all contribute. Experiments of this kind use additional controls to separate those possibilities.
A widely used internally quenched design, first described by Knight, Willenbrock and Murphy for the matrix metalloproteinases.8 The donor (7-methoxycoumarin-4-yl)acetyl (Mca) sits at the N-terminus and the quencher 2,4-dinitrophenyl is carried on a 2,3-diaminopropionyl residue, so that cleavage of the Gly-Leu bond separates the two.
Mca-Pro-Leu-Gly-Leu-Dpa-Ala-Arg-NH2
The authors report excitation and emission at 328 nm and 393 nm, and a 190-fold increase in fluorescence on cleavage, which allows a continuous assay at enzyme concentrations comparable with those used for macromolecular substrates.8 LifeTein synthesizes substrates of this type to order; tell us the donor, the quencher, the cleavage site and the target enzyme.
Each dye below has its own page with its spectra, its attachment chemistry and the reason to choose it over the alternatives in the same channel. They are listed together, with maxima and laser lines, on the dye comparison page.
We are not limited to the list above. Dyes from the ATTO, DyLight, HiLyte and AZDye ranges, Texas Red, ROX, Alexa Fluor 594, and near-infrared labels including ICG analogs can be quoted on request, as maleimides for cysteine labeling or as NHS esters for amine labeling. Tell us the dye name and the reactive form you need, and we will confirm availability with the quote.
Need help selecting a fluorescent dye or spacer?
Send us your peptide sequence, intended assay, target wavelength, and preferred dye. We can help review practical labeling options for your project.
Please send us your peptide sequence, desired dye, labeling position, spacer preference, purity, quantity, and application. For FRET peptides, please include the donor, acceptor or quencher, cleavage site, and intended enzyme or assay. We send a quote within 24 hours.
If you already have a quote number, you can place your order online or send the signed quote form with your purchase order.